Bulk current injection probes are used to inductively couple large RF currents into conductors passing through. They come in two different styles, a clamping style that can be used for hard to access cable bundles and a window style to pass wires and cables through. Signal, control, and power circuits of EUT (equipment under test) are the conductors when testing for conducted immunity. Bulk current injection probes operate as a single turn primary, multiple turn secondary transformer, by placing low series impedance in the probed power line while pushing a functional signal to a 50ohm receiver. The ratio of output voltage into a standard load divided by the net current movingthrough the probe equals the current probe's transfer impedance.MIL-STD-461,IEC 61000-4-6, andISO 11452-4commonly require the injection of low-level RF signals and high-frequency current into wires and cable bundles, making a current injection probe an essential item to adhere to testing requirements.

Avalon Test Equipment carries a variety of bulk current injection probes from top manufacturers (Com-Power,A.H. Systems, and more) to meet your testing requirements. Rent from Avalon and Test With Confidence®.

Bulk Current Injection (BCI) Probes (1)

Read More

Read Less

3 Items in Grid 4 Items in Grid List

Bulk Current Injection (BCI) Probes (3)

(Video) Bulk Current Injection (BCI) Test Probe Calibration per ISO 11452-4

Bulk Current Injection (BCI) Probes (4)

Teseq CIP 9136A Bulk Current Injection Test Clamp

Wide frequency range 10 kHz - 400 MHz High power handling (up to 1 kW) Ideal for automotive BCI testing e.g. ISO 11452-4, RTCA/DO-160 section 20, MIL-STD-461 and manufacture‘s requirements Meets IEC/EN 61000-4-6 Replacement for CIP 36A & 37A as specified in Defence Standard 59-41

Bulk Current Injection (BCI) Probes (6)

A.H. Systems ICP-522 RF Current Injection Probe

(Video) Bulk Current Injection Made Easy - Homemade Probe Pre-compliance Immunity Test

1 MHz–400 MHz

Bulk Current Injection (BCI) Probes (9)

Fischer F-120-9A Bulk Current Injection Probe

Bulk Current Injection Probe

(Video) Bulk Current Injection Immunity testing BCI Tests Automotive v1 0

Bulk Current Injection (BCI) Probes (10)

Fischer F-120-1 Bulk Current Injection Probe

The Fischer Custom Communications FCC F-120-1 Bulk Current Injection Probe has been designed to extend the use of conducted immunity testing over the bandwidth of 10 kHz – 175 MHz

Bulk Current Injection (BCI) Probes (12)

Fischer BCICF-1 Bulk Current Injection Probe Fixtures

Part of the test equipment required by most of the Bulk Current Injection test procedure specifications. Allows the user the quickly and easily calibrate the injection probe prior to performing compliance testing.

Bulk Current Injection (BCI) Probes (13)

Fischer BCICF-2 Bulk Current Injection Probe Fixtures

Injection Probe calibration fixtures are a part of the test equipment required by most of the Bulk Current Injection Test Procedure Specifications. This test fixture allows the user to quickly and easily calibrate the injection probe prior to performing the compliance testing.

(Video) BCI Setup with External RF Amplifier Walkthrough & Guide

Bulk Current Injection (BCI) Probes (14)

Com-Power CLCI-100 Current Probe

The Com-Power Current Injection Probes are used for RF conducted immunity testing per IEC 61000-4-6, CISPR 16-1-2, RTCA DO-160, and MIL-STD 461.

Bulk Current Injection (BCI) Probes (15)

EMC Partner CN-BT6 Injection Probe

Current injection probe for requirements CS115 and CS116 of MIL-STD-461

Bulk Current Injection (BCI) Probes (16)

Fischer FCC-BCICF-4 Bulk Current Injection Probe Fixtures

(Video) Com-Power CLCI-400 Bulk Current Injection Probe

Videos

1. Bulk Current Injection Testing, RFCI System Calibration to 10V per IEC/EN 61000-4-6 - The EMC Shop
(The EMC Shop)
2. RFCI-Auto ISO 11452-4 400mA RF Conducted Disturbances Testing - The EMC Shop
(The EMC Shop)
3. Pre-compliance Immunity Test - A Capacitively Coupled Pin Injection method
(Mach One Design EMC)
4. Teseq NSG 4070 BCI Setup - Current Clamp IEC 61000-4-6 Calibration Setup
(Transient Specialists)
5. Electronics: Bulk current injection - Resonant frequency of ESD protection diode CAN bus
(Roel Van de Paar)
6. EMC Pre-Compliance - Using RF Current Probes
(Power Conversion Limited)
Top Articles
Latest Posts
Article information

Author: Chrissy Homenick

Last Updated: 06/05/2023

Views: 6021

Rating: 4.3 / 5 (74 voted)

Reviews: 89% of readers found this page helpful

Author information

Name: Chrissy Homenick

Birthday: 2001-10-22

Address: 611 Kuhn Oval, Feltonbury, NY 02783-3818

Phone: +96619177651654

Job: Mining Representative

Hobby: amateur radio, Sculling, Knife making, Gardening, Watching movies, Gunsmithing, Video gaming

Introduction: My name is Chrissy Homenick, I am a tender, funny, determined, tender, glorious, fancy, enthusiastic person who loves writing and wants to share my knowledge and understanding with you.