This chapter includes the following sections:
Interconnect Features
A Cisco UCS 6200 series fabric interconnect is a top-of-rack fabric interconnect that provides Ethernet and Fibre Channel to all servers in the UCS system. Servers connect to the fabric interconnect, and it connects to the LAN or SAN.
This family of fabric interconnects connect UCS servers to 10 Gigabit Ethernet 1, 2, 4, and 8 Gbps Fibre Channel networks, and provides consolidated I/O connectivity to both production Ethernet LANs and Fibre Channel SANs in a cost-effective, high-performance, low-latency environment.
The Cisco UCS 6200 series has the following characteristics:
-
The UCS 6248 UP fabric interconnect is a one-rack-unit (1 RU), 10-Gigabit Ethernet and FCoE device that offers up to 960-Gbps throughput and up to 48 ports. It has 32 1- or 10-Gbps fixed small form-factor pluggable plus (SFP+) ports and one expansion slot. The Cisco UCS 6248 UP has 32 ports on the base system and can be upgraded with one expansion module providing an additional 16 ports.
-
The UCS 6296 UP fabric interconnect is a two-rack-unit (2 RU), 10-Gigabit Ethernet and FCoE device that offers up to 1920-Gbps throughput and up to 96 ports. It has 48 1- or 10-Gbps fixed SFP+ ports and three expansion slots. The Cisco UCS 6248 UP has 48 ports on the base system and can be upgraded with three expansion modules providing an additional 48 ports.
-
Universal port functionality allows Ethernet or Fibre Channel over Ethernet (FCoE) physical port types to be selected in software.
-
Slots on the back of the switch for an expansion module. You can use the UCS EIGUP module.
(Video) Cisco UCS configuration, Fabric interconnect setup -
Slots on the front of the chassis for hot swap-capable power supplies.
-
Slots on the front of the chassis for fan modules.
-
One USB port at the front of the switch.
Cisco UCS 6248 UP Fabric Interconnect Chassis
The Cisco UCS 6248 UP chassis is 1 RU, 1.72 inches tall, 17.3 inches wide and 30.0 inches deep. It mounts in a standard 19-inch rack (the Cisco R Series rack is an ideal choice). The chassis has two power supplies and two fan modules on the front of the chassis, and it has network ports on the rear of the chassis and has one USB port (usb1:) at the front.
Thirty-two fixed 10-Gigabit Ethernet ports and an expansion modules slot supporting 16 ports are at the rear of the switch. The airflow is front to back.
![Cisco UCS 6200 Series Fabric Interconnect Hardware Installation Guide - Product Overview [Cisco UCS 6200 Series Fabric Interconnects] (1) Cisco UCS 6200 Series Fabric Interconnect Hardware Installation Guide - Product Overview [Cisco UCS 6200 Series Fabric Interconnects] (1)](https://i0.wp.com/www.cisco.com/c/dam/en/us/td/i/200001-300000/230001-240000/236001-237000/236703.eps/_jcr_content/renditions/236703.jpg)
1 | Management (10/100/1000) port, console port, and USB port | 3 | Two power supplies (AC shown) |
2 | Two fan modules |
The rear of the Cisco UCS 6248 UP chassis has 32 fixed 10-Gigabit, Fiber Channel over Ethernet-capable SFP+ Ethernet ports and 1 slot for an optional expansion module.
![Cisco UCS 6200 Series Fabric Interconnect Hardware Installation Guide - Product Overview [Cisco UCS 6200 Series Fabric Interconnects] (2) Cisco UCS 6200 Series Fabric Interconnect Hardware Installation Guide - Product Overview [Cisco UCS 6200 Series Fabric Interconnects] (2)](https://i0.wp.com/www.cisco.com/c/dam/en/us/td/i/200001-300000/230001-240000/236001-237000/236704.eps/_jcr_content/renditions/236704.jpg)
1 | 32 fixed 10-Gigabit Ethernet ports | 2 | 16 Expansion module ports |
![Cisco UCS 6200 Series Fabric Interconnect Hardware Installation Guide - Product Overview [Cisco UCS 6200 Series Fabric Interconnects] (3) Cisco UCS 6200 Series Fabric Interconnect Hardware Installation Guide - Product Overview [Cisco UCS 6200 Series Fabric Interconnects] (3)](https://i0.wp.com/www.cisco.com/c/dam/en/us/td/i/200001-300000/230001-240000/236001-237000/236705.eps/_jcr_content/renditions/236705.jpg)
1 | System status LED and beaconing LED/button | 3 | 16 port Expansion module |
2 | 32 fixed 10-Gigabit Ethernet ports |
The front connector ports are in a 2x2 stacked RJ-45 jack.
![Cisco UCS 6200 Series Fabric Interconnect Hardware Installation Guide - Product Overview [Cisco UCS 6200 Series Fabric Interconnects] (4) Cisco UCS 6200 Series Fabric Interconnect Hardware Installation Guide - Product Overview [Cisco UCS 6200 Series Fabric Interconnects] (4)](https://i0.wp.com/www.cisco.com/c/dam/en/us/td/i/300001-400000/330001-340000/330001-331000/330339.eps/_jcr_content/renditions/330339.jpg)
1 | Beaconing LED/button | 5 | Network management port |
2 | System Status LED | 6 | Console port |
3 | UCS cross connect port L1 | 7 | USB port |
4 | UCS cross connect port L2 |
LED | Status | Description |
---|---|---|
Left | Off | No link |
Solid green | Physical link | |
Right | Off | No activity |
Blinking green | Activity |
Cisco UCS 6296 UP Fabric Interconnect Chassis
The Cisco UCS 6296 UP chassis is 2 RU or 3.47 inches (8.8 cm) tall, 17.3 inches (43.9 cm) wide, and 29.5 inches (74.9 cm) deep. It is designed to be mounted in a standard 19-inch wide rack. The front of the switch has a USB port, four Ethernet and ports (two cross-connect ports, one management port, and one console port), two power supplies, and four fan modules.
![Cisco UCS 6200 Series Fabric Interconnect Hardware Installation Guide - Product Overview [Cisco UCS 6200 Series Fabric Interconnects] (5) Cisco UCS 6200 Series Fabric Interconnect Hardware Installation Guide - Product Overview [Cisco UCS 6200 Series Fabric Interconnects] (5)](https://i0.wp.com/www.cisco.com/c/dam/en/us/td/i/200001-300000/230001-240000/237001-238000/237867.jpg)
1 | USB port | 4 | System status LED |
2 | Management and console ports (two RJ-45 Ethernet connector ports on the left, a RJ-45 network management connector on the upper right, and a console connector on the lower right) | 5 | Two power supplies |
3 | Identifier LED | 6 | Four fan modules |
The management and console ports are in a 2 x 2 stacked RJ-45 jack.
![Cisco UCS 6200 Series Fabric Interconnect Hardware Installation Guide - Product Overview [Cisco UCS 6200 Series Fabric Interconnects] (6) Cisco UCS 6200 Series Fabric Interconnect Hardware Installation Guide - Product Overview [Cisco UCS 6200 Series Fabric Interconnects] (6)](https://i0.wp.com/www.cisco.com/c/dam/en/us/td/i/300001-400000/330001-340000/330001-331000/330339.eps/_jcr_content/renditions/330339.jpg)
1 | Beaconing LED/button | 5 | Network management port |
2 | System Status LED | 6 | Console port |
3 | UCS cross connect port L1 | 7 | USB port |
4 | UCS cross connect port L2 |
The rear of the Cisco UCS 6296 UP chassis has 48 fixed 10-Gigabit Ethernet data ports on the bottom and three slots for optional expansion modules on top.
![Cisco UCS 6200 Series Fabric Interconnect Hardware Installation Guide - Product Overview [Cisco UCS 6200 Series Fabric Interconnects] (7) Cisco UCS 6200 Series Fabric Interconnect Hardware Installation Guide - Product Overview [Cisco UCS 6200 Series Fabric Interconnects] (7)](https://i0.wp.com/www.cisco.com/c/dam/en/us/td/i/200001-300000/230001-240000/237001-238000/237866.jpg)
1 | Expansion modules, shown here with three 16-port Universal GEM2 modules | 3 | System status LED |
2 | Identifier LED | 4 | 48 fixed 1- and 10-Gigabit Ethernet ports |
UCS Unified Port Expansion Module
Expansion modules allow Cisco UCS 6200 Series Fabric Interconnect to be configured as cost-effective 10-Gigabit Ethernet fabric interconnects and as I/O consolidation platforms with native Fibre Channel connectivity. The Cisco UCS 6248 UP has one slot for an optional expansion module. The Cisco UCS 6296 has three slots for an optional expansion module. Only the 16-port UCS E16UP hot-pluggable expansion module using the small form factor pluggable plus (SFP+) interface is supported.
![Cisco UCS 6200 Series Fabric Interconnect Hardware Installation Guide - Product Overview [Cisco UCS 6200 Series Fabric Interconnects] (8) Cisco UCS 6200 Series Fabric Interconnect Hardware Installation Guide - Product Overview [Cisco UCS 6200 Series Fabric Interconnects] (8)](https://i0.wp.com/www.cisco.com/c/dam/en/us/td/i/200001-300000/230001-240000/236001-237000/236707.eps/_jcr_content/renditions/236707.jpg)
Cisco UCS 6248 UP Port Numbering
Each individual port is numbered, and groups of ports are numbered based on their function. The ports are numbered top to bottom and left to right.
There are 32 to 48 ports on the Cisco UCS 6248 UP, depending on whether an expansion module is installed. Each individual port is numbered, and groups of ports are numbered based on their function. The ports are numbered from top to bottom and left to right.
![Cisco UCS 6200 Series Fabric Interconnect Hardware Installation Guide - Product Overview [Cisco UCS 6200 Series Fabric Interconnects] (9) Cisco UCS 6200 Series Fabric Interconnect Hardware Installation Guide - Product Overview [Cisco UCS 6200 Series Fabric Interconnects] (9)](https://i0.wp.com/www.cisco.com/c/dam/en/us/td/i/200001-300000/230001-240000/236001-237000/236720.eps/_jcr_content/renditions/236720.jpg)
1 | Slot 1, 32 fixed ports | 2 | Slot 2, 16 port Expansion module (UCS E16UP) |
Cisco UCS 6296 UP Port Numbering
Each port on the Cisco UCS 6296 UP is numbered, and groups of ports are numbered based on their function. The ports are numbered top to bottom and left to right. The 48 fixed ports support 8-, 4-, 2-, or 1-Gbps Fibre Channel transceivers and 1- or 10-Gigabit Ethernet transceivers.
![Cisco UCS 6200 Series Fabric Interconnect Hardware Installation Guide - Product Overview [Cisco UCS 6200 Series Fabric Interconnects] (10) Cisco UCS 6200 Series Fabric Interconnect Hardware Installation Guide - Product Overview [Cisco UCS 6200 Series Fabric Interconnects] (10)](https://i0.wp.com/www.cisco.com/c/dam/en/us/td/i/300001-400000/330001-340000/331001-332000/331630.eps/_jcr_content/renditions/331630.jpg)
1 | Port numbering for the 48 fixed ports in slot 1 | 3 | Port numbering for the 16-port GEM in slot 3 |
2 | Port numbering for the 16-port GEM in slot 2 | 4 | Port numbering for the 16-port GEM in slot 4 |
Cabling Considerations for Fabric Port Channels
When you configure the links between the Cisco UCS 2200 Series FEX and a Cisco UCS 6200 series fabric interconnect in fabric port channel mode, the available virtual interface namespace (VIF) on the adapter varies depending on where the FEX uplinks are connected to the fabric interconnect ports.
Inside the 6248 fabric interconnect there are six sets of eight contiguous ports, with each set of ports managed by a single chip. When all uplinks from an FEX are connected to a set of ports managed by a single chip, Cisco UCS Manager maximizes the number of VIFs used in service profiles deployed on the blades in the chassis. If uplink connections from an IOM are distributed across ports managed by separate chips, the VIF count is decreased.
![Cisco UCS 6200 Series Fabric Interconnect Hardware Installation Guide - Product Overview [Cisco UCS 6200 Series Fabric Interconnects] (11) Cisco UCS 6200 Series Fabric Interconnect Hardware Installation Guide - Product Overview [Cisco UCS 6200 Series Fabric Interconnects] (11)](https://i0.wp.com/www.cisco.com/c/dam/en/us/td/i/300001-400000/330001-340000/330001-331000/330345.eps/_jcr_content/renditions/330345.jpg)
![]() Caution | Adding a second link to a fabric-port-channel port group is disruptive and will automatically increase the available amount of VIF namespace from 63 to 118. Adding further links is not disruptive and the VIF namespace stays at 118. |
![]() Caution | Linking a chassis to two fabric-port-channel port groups does not affect the VIF namespace unless it is manually acknowledged. The VIF namespace is then automatically set to the smaller size fabric port-channel port group usage (either 63 or 118 VIFs) of the two groups. |
For high availability cluster-mode applications, we strongly recommend symmetric cabling configurations. If the cabling is asymmetric, the maximum number of VIFs available is the smaller of the two cabling configurations.
For more information on the maximum number of VIFs for your Cisco UCS environment, see the Configuration Limits document for your hardware and software configuration.
Power Supplies
Cisco PID | Fabric Interconnect | Source | Wattage |
---|---|---|---|
UCS-PSU-6248UP-AC | Cisco UCS 6248 UP | 110 VAC | 390 |
UCS-PSU-6248UP-DC | Cisco UCS 6248 UP | -48 VDC | 390 |
UCS-PSU-6296UP-AC | Cisco UCS 6296 UP | 110 VAC | 680 |
The fabric interconnect uses a front-end power supply. The chassis has slots for two power supplies. Two power supplies can be used for redundancy, but the fabric interconnect is fully functional with one power supply. Power supplies have two LEDs: one for power status and one for failure condition.
![Cisco UCS 6200 Series Fabric Interconnect Hardware Installation Guide - Product Overview [Cisco UCS 6200 Series Fabric Interconnects] (14) Cisco UCS 6200 Series Fabric Interconnect Hardware Installation Guide - Product Overview [Cisco UCS 6200 Series Fabric Interconnects] (14)](https://i0.wp.com/www.cisco.com/c/dam/en/us/td/i/300001-400000/330001-340000/330001-331000/330340.eps/_jcr_content/renditions/330340.jpg)
1 | Fault LED | 2 | Power LED |
![Cisco UCS 6200 Series Fabric Interconnect Hardware Installation Guide - Product Overview [Cisco UCS 6200 Series Fabric Interconnects] (15) Cisco UCS 6200 Series Fabric Interconnect Hardware Installation Guide - Product Overview [Cisco UCS 6200 Series Fabric Interconnects] (15)](https://i0.wp.com/www.cisco.com/c/dam/en/us/td/i/300001-400000/330001-340000/330001-331000/330341.eps/_jcr_content/renditions/330341.jpg)
1 | Amber LED indicates a failure condition. | 2 | Green LED indicates the input power status. |
![Cisco UCS 6200 Series Fabric Interconnect Hardware Installation Guide - Product Overview [Cisco UCS 6200 Series Fabric Interconnects] (16) Cisco UCS 6200 Series Fabric Interconnect Hardware Installation Guide - Product Overview [Cisco UCS 6200 Series Fabric Interconnects] (16)](https://i0.wp.com/www.cisco.com/c/dam/en/us/td/i/200001-300000/230001-240000/237001-238000/237868.jpg)
1 | Failure (top) and Power (bottom) LEDs | 3 | Release lever |
2 | Handle |
Power Supply Condition | Power LED Status | Fail LED Status |
---|---|---|
No AC power to all power supplies. | Off | Off |
Power supply failure, including over voltage, over current, over temperature, and fan failure. | Off | On |
Power supply warning events where the power supply continues to operate. These events include high temperature, high power, and slow fan. | Off | 1 Hz Blinking |
AC present, 3.3 voltage standby (VSB) on, and the power supply unit is off. | 1 Hz blinking | Off |
Power supply on and OK. | On | Off |
If one power supply is installed in the chassis, but the other power supply slot is empty, a blank filler panel (N10-S1BLKP=) should be used to cover the empty slot.
Fan Module
The Cisco UCS 6248 UP fabric interconnect has slots for two fan modules (also called fan trays). Each fan module houses four fans. The combination of four fans per module and two modules provides the chassis with eight fans.
![Cisco UCS 6200 Series Fabric Interconnect Hardware Installation Guide - Product Overview [Cisco UCS 6200 Series Fabric Interconnects] (17) Cisco UCS 6200 Series Fabric Interconnect Hardware Installation Guide - Product Overview [Cisco UCS 6200 Series Fabric Interconnects] (17)](https://i0.wp.com/www.cisco.com/c/dam/en/us/td/i/300001-400000/330001-340000/330001-331000/330342.eps/_jcr_content/renditions/330342.jpg)
1 | Fan Tray Status LED |
The Cisco UCS 6296 UP switch has four fan modules with one fan each.
![Cisco UCS 6200 Series Fabric Interconnect Hardware Installation Guide - Product Overview [Cisco UCS 6200 Series Fabric Interconnects] (18) Cisco UCS 6200 Series Fabric Interconnect Hardware Installation Guide - Product Overview [Cisco UCS 6200 Series Fabric Interconnects] (18)](https://i0.wp.com/www.cisco.com/c/dam/en/us/td/i/200001-300000/230001-240000/239001-240000/239022.eps/_jcr_content/renditions/239022.jpg)
1 | Captive screw | 3 | Handle |
2 | Status LED |
The bicolor fan module LED indicates fan tray health. Green indicates normal operation, while amber indicates a fan failure.
LED Descriptions
The fabric interconnect has three chassis status LEDs.
LED | Location | Function | Color | Status | Description |
---|---|---|---|---|---|
System Status LED | Front | Power/Health | Green | Solid On | System is on and operating normally |
Off | Switch is powered off | ||||
Amber | On | Fault condition | |||
Fan Tray Status | Fan trays (front) | Fan tray health indicator (multi color) | Green | On | Fan tray is operating normally |
Amber | On | Fan failure has occurred within the fan tray | |||
PSU Status | Power supply (front) | PSU Health (multi color) | Green | OFF | No AC power to power supply |
Solid On | Power supply on and OK | ||||
Amber | Solid On | Power supply failures, overvoltage, overcurrent, overtemperature | |||
1 Hz blinking | AC present, 3.3 VSB on, PSU is off | ||||
OFF | Operating normally | ||||
Beaconing | Front of chassis | Identify selected chassis | Blue | Solid on | Chassis is selected |
Off | Chassis is not selected |
Port Level LEDs
There are port activity LEDs on the chassis and on the expansion modules.
Color | Description |
---|---|
Green (blinking) | Link is up, enabled, and active. |
Amber | Link is administratively disabled. |
Amber (blinking) | POST or operational error. |
Off | Link is down. |
Supported Transceivers
The fabric interconnect supports SFP+ Ethernet transceivers, SFP transceivers, and SFP Fibre Channel transceivers. Specifications for these transceivers are at this URL:
http://www.cisco.com/en/US/docs/interfaces_modules/transceiver_modules/installation/note/78_15160.html
SFP+ Transceivers
The high bandwidth of 10-Gigabit Ethernet poses challenges to transmissions that are met by the transceiver and cabling options supported by the Cisco UCS 6200 platform.
The enhanced SFP+ 10-Gigabit Ethernet transceiver module is a bidirectional device with a transmitter and receiver in the same physical package. It has a 20-pin connector on the electrical interface and duplex LC connector on the optical interface.
Cisco SFP | Description |
---|---|
FET-10G | 10G SFP+ Fabric extender transceiver module. The FET-10G SFP is only supported on connections from a 6200 Fabric Interconnect to a Nexus 2000 or UCS IOM when the port is setup as a server port. This SFP cannot be used for uplink ports. |
SFP-10G-SR | 10GBASE-SR SFP+ module (multimode fiber [MMF]) |
SFP-10G-LR | 10GBASE-LR SFP+ module (single-mode fiber [SMF]) |
SFP-H10GB-CU1M | 10GBASE-CU SFP+ cable 1 m (Twinax cable) |
SFP-H10GB-CU3M | 10GBASE-CU SFP+ cable 3 m (Twinax cable) |
SFP-H10GB-CU5M | 10GBASE-CU SFP+ cable 5 m (Twinax cable) |
SFP-H10GB-ACU7M | 10GBASE-CU SFP+ cable 7 m (Twinax cable) |
SFP-H10GB-ACU10M | 10GBASE-CU SFP+ cable 10 m (Twinax cable) |
GLC-T | 1000BASE-T SFP |
GLC-SX-MM | GE SFP, LC connector SX transceiver (MMF) |
GLC-LH-SM | GE SFP, LC connector LX/LH transceiver (SMF) |
SFP-GE-T | 1000BASE-T SFP, extended temperature range |
SFP-GE-S | GE SFP, LC connector SX transceiver (MMF), extended temperature range and digital optical monitoring (DOM) |
SFP-GE-L | GE SFP, LC connector LX/LH transceiver (SMF), extended temperature range and DOM |
DS-SFP-FC4G-SW | 4-Gbps Fibre Channel SW SFP, LC (for FC configured Unified ports) |
DS-SFP-FC4G-LW | 4-Gbps Fibre Channel LW SFP, LC (for FC configured Unified ports) |
DS-SFP-FC8G-SW | 8-Gbps Fibre Channel SW SFP+, LC(for FC configured Unified ports) |
DS-SFP-FC8G-LW | 8-Gbps Fibre Channel LW SFP+, LC (for FC configured Unified ports) |
![]() Note | The maximum length of fiber optic runs is limited to 300 meters. This is imposed by our use of 802.3X/802.1Qbb Priority Pauses. SFP-10G-LR is supported between fabric interconnect and FEX, but the 300 m limit still applies. |
SFP Transceivers
The SFP 1 -Gigabit Ethernet transceiver module is a bidirectional device with a transmitter and receiver in the same physical package.
Model | Description |
---|---|
GLC-T | 1-Gigabit Ethernet copper SFP module |
GLC-SX-MM | 1-Gigabit Ethernet—short range (550m max) SFP module |
GLC-LH-SM | 1-Gigabit Ethernet—long range (10km) SFP module |
![]() Note | The maximum length of fiber optic runs is limited to 300 meters. This is imposed by our use of 802.3X/802.1Qbb Priority Pauses. SFP-10G-LR is supported between fabric interconnect and I/O Module, but the 300 m limit still applies. |
SFP+ Copper Cables
Copper cables are available for use with the 10-Gigabit Ethernet SFP+ module.
Model | Description |
---|---|
SFP-H10GB-CU1M | 10GBASE-CU SFP+ 1-meter cable |
SFP-H10GB-CU3M | 10GBASE-CU SFP+ 3-meter cable |
SFP-H10GB-CU5M | 10GBASE-CU SFP+ 5-meter cable |
SFP-H10GB-ACU7M= | 10GBASE-CU SFP+ 7-meter cable |
SFP-H10GB-ACU10M= | 10GBASE-CU SFP+ 10-meter cable |
On the Cisco UCS 6200 platforms, you can use an innovative Twinax copper cable that connects to standard SFP+ connectors for in-rack use, and on optical cable for longer cable runs.
For in-rack or adjacent-rack cabling, the Cisco UCS 6200 platform supports SFP+ direct-attach 10-Gigabit Ethernet copper, which integrates transceivers with Twinax cables into an energy efficient, low-cost, and low-latency solution. SFP+ direct-attach 10-Gigabit Twinax copper cables use only 0.1 watts of power per transceiver and introduce only approximately 0.25 microsecond of latency per link.
For longer cable runs, the Cisco UCS 6200 platform supports multimode, short-reach optical SFP+ transceivers. These optical transceivers use approximately 1 W per transceiver and have a latency of less than 0.1 microsecond.
Connector (Media) | Cable | Distance | Power (each side) | Transceiver Latency (Link) | Standard |
---|---|---|---|---|---|
SFP+ CU copper | Twinax | 5 m | ~ 0.1 W | ~ 0.1 microseconds | SFF 8431 |
SFP+ ACU copper | Active Twinax | 7 m/ 10 m | ~ 0.5 W | ~ 6.8 nanoseconds | SFF 8461 |
SFP+ SR MMF and SR | MM OM2 MM OM3 | 82 m/ 300 m | 1 W | ~ 0 microseconds | IEEE 802.3ae |
SFP Fibre Channel Transceivers
The Cisco UCS 6200 series fabric interconnects support multimode 850 nm 4 Gbps and 8 Gbps SFPs with 150 m reach.
Model | Description |
---|---|
Cisco DS-SFP-FC4G-SW | 4 Gbps Fibre Channel-SW SFP, LC (for FC configured Unified ports) |
Cisco DS-SFP-FC4G-LW | 4 Gbps Fibre Channel-LW SFP, LC, (10 km reach) (for FC configured Unified ports) |
Cisco DS-SFP-FC8G-SW | 8-Gbps Fibre Channel SW SFP+, LC (for FC configured Unified ports) |
Cisco DS-SFP-FC8G-LW | 8-Gbps Fibre Channel LW SFP+, LC (for FC configured Unified ports) |
![]() Note | The maximum length of fiber optic runs from the fabric interconnect to a chassis is limited to 300 meters. This restriction is imposed by the use of 802.3X/802.1Qbb Priority Pauses. |
FAQs
What is Cisco UCS fabric interconnects? ›
What is a Fabric Interconnect? Fabric interconnects mostly exist in the Cisco world. They are devices that connect servers and other network-attached equipment to the rest of the network. Fabric interconnects are typically found in the UCS line of Cisco products and services.
When did the Cisco FI 6200 come out? ›The Cisco UCS 6200 Series offers line-rate, low-latency, lossless 10 Gigabit Ethernet and Fiber Channel over Ethernet (FCoE) functions. The Cisco UCS 6200 Series provides the management and communication backbone for the Cisco UCS B-Series Blade Servers and UCS 5100 Series blade server chassis.
What is the default password for Cisco UCS 6200 Series fabric interconnect? ›Cisco recommends changing the password once access is gained using the default “Cisco1234” password.
What is a fabric Cisco? ›Cisco Unified Fabric is the interconnection point for. applications, stored data, and users that can help you: • Build an intelligent, high-performing infrastructure. with multidimensional scalability for the data center.
What is the purpose of Fabric Interconnect? ›The Fabric Interconnect (FI) is the core component of a UCS solution, providing network, storage, and unified management capabilities to servers. Fabric Interconnects are typically configured as highly available clustered pairs in production environments and provide active-active data traffic.
What is ucs fi 6296UP? ›The Cisco UCS 6296UP 96-Port Fabric Interconnect is a core part of the Cisco unified computing system. typically deployed in redundant pairs, the Cisco UCS 6296UP Fabric Interconnects provide uniform access to both networks and storage.
When did Cisco UCS come out? ›Cisco Unified Computing System (UCS) is a data center server computer product line composed of server hardware, virtualization support, switching fabric, and management software, introduced in 2009 by Cisco Systems.
Who makes Cisco routers? ›Cisco Systems was founded shortly thereafter, and the company's first product was the Router. The company that would become Cisco Systems was spun out of SCI, later known as Sun Microsystems, in 1982.
What is the difference between Cisco UCS B and C? ›Cisco UCS B-series blade servers sits inside the UCS chassis and are managed by UCS manager running on Fabric Interconnect. Cisco UCS C-series rack server are independent 1RU or 2RU size servers, which can be independently managed or via UCS FI.
What is the benefit of Cisco UCS? ›
While the servers compared are based on similar specs, the Cisco UCS provides a lower hardware cost by deploying simplified intra-chassis switching for blades and minimizing the number of adapters and ports required for rack servers.
What is the difference between Cisco UCS Manager and UCS Central? ›About Cisco UCS Central
Cisco UCS Central does not replace Cisco UCS Manager, which is the basic engine for managing a Cisco UCS domain. Instead, it builds on the capabilities provided by Cisco UCS Manager and works with Cisco UCS Manager to effect changes in individual domains.
The default user name is admin and the default password is password for your initial login. This information is stored in the database. Both the Fabric Manager Server and the Web Server share the same user credential database. Double-click the Fabric Manager Client icon on your workstation.
Which cable is used to connect to the CLI on a fabric interconnect? ›An RJ-45 rollover cable provided in the fabric interconnect accessory kit. Network cabling is routed to the location of the installed fabric interconnect. Connect an RJ-45 rollover cable to the console port on the fabric interconnect. You can find this cable in the accessory kit.
What is the default password for cisco Integrated Management Controller? ›Note The default username and password for CIMC-E is “admin” and “password” respectively.
What is the difference between a network and a fabric? ›A fabric refers collectively to the equipment and configuration that implements a network. A network fabric describes the network topology in which components pass data to each other through interconnecting switches.
Is switching fabric hardware or software? ›Switching fabric is a combination of hardware and software that controls traffic to and from a network node with the use of multiple switches.
What does a Cisco fabric extender do? ›Cisco Nexus Fabric Extenders (FEXs) provide ToR connectivity for Nexus 5000 and 7000 series switches. This 9-step plan shows you how to bring a FEX online, and includes configuration tips and code examples.
Is Cisco Fabric Interconnect a switch? ›The Cisco UCS 6332-16UP 40-Port Fabric Interconnect is a 1RU 40 Gigabit Ethernet and FCoE interconnect offering up to 2.43-Gbps throughput with 40 ports (Figure 5). The switch has 24 x 40 Gigabit Ethernet and FCoE ports and 16 unified ports.
Is a fabric interconnect active or passive? ›Fabric interconnects are typically deployed in active–active redundant pairs providing uniform access to storage arrays and other network resources.
How do you power off fabric interconnects in Cisco UCS? ›
UCS Fabric Interconnects are designed for continuous operation. In a production environment, there is no need to shut down or reboot Fabric Interconnects. Therefore, there is no power button on UCS Fabric Interconnects. In order to shut down UCS Fabric Interconnect, it is required to pull the power cable manually.
What UCS means? ›unified computing system (UCS)
What is the difference between server port and uplink port in UCS? ›Server Port: Port is configured for southbound connection to an IOM Fabric Extender (FEX) module in a blade chassis. Uplink Port: Port is configured for northbound connection to the upstream Ethernet switch. Uplink ports are always configured as trunk ports.
What is uplink port in UCS? ›Uplink Ethernet Ports - Uplink Ethernet ports handle ethernet traffic between the UCS fabric interconnect and the next layer of the network. All network-bound Ethernet traffic is pinned to one of these ports. You can configure uplink Ethernet ports on either the fixed module or an expansion module.
Is Cisco discontinuing UCS? ›Cisco announces the end-of-sale and end-of life dates for the Cisco UCS Manager Release 4.0. The last day to order the affected product(s) is February 7, 2022.
Is Cisco UCS a hypervisor? ›The Cisco UCS cluster is a grouping of hypervisors that can be distributed across multiple hosts.
What is required for Cisco UCS? ›If you register 100 Cisco UCS domains , the minimum storage space required to store statistics data for 1 year would be 2 TB. The minimum memory required for client system is 4 GB. However if you have 40 or more registered Cisco UCS Domains, it is recommended to have at least 8 GB memory on the client system.
Who is Cisco's biggest competitor? ›- Juniper.
- Huawei.
- Arista Networks.
- Dell Technologies.
- VMware.
- HPE (Aruba)
- Extreme Networks.
- NETGEAR.
A Cisco router connects different networks together whereas, a switch connects multiple devices together to create a network. 2. Routers work on the Physical layer; Data link layer and the Network layer whereas Switches, as well as advanced switches, work on the Data link layer and the Network layer too.
What is the most famous Cisco router? ›Cisco Routers For Home Use
For the home, Cisco offers a range of routers. The most popular out there is the Cisco 800 Series.
What is the difference between Cisco UCS manager and director? ›
Cisco UCS Director is not a replacement for Cisco UCS Manager. Rather, Cisco UCS Director uses orchestration to automate some of the steps required to configure a Cisco UCS domain. In this way, Cisco UCS Director provides a statistical analysis of the data and a converged view of each pod.
What are the different modes of Cisco UCS? ›UCS Fabric Interconnect supports two types of switching modes: End Host Mode (EHM) and standard Ethernet switching mode. The default switching mode is the End Host Mode which eliminates the use of Spanning Tree Protocol (STP) on Fabric Interconnect.
How do I connect to Cisco UCS? ›- Select the Equipment tab in the Navigation Pane.
- Expand Fabric Interconnects > Fabric Interconnect A > Fixed Module > Unconfigured Ports.
- Right click on the desired port object.
- Select Configure as Server Port or select Configure as Server Port under Actions in the Work Pane.
Cisco products are designed to improve productivity and customer experience. Cisco network switches provide application visibility and control, as well as intelligent traffic management to help prioritise business-critical traffic over recreational traffic.
What is the benefit of Cisco VPN? ›Provide secure communications with access rights tailored to individual users, such as employees, contractors, or partners.
What are the benefits of having Cisco UCS and Cisco MDS together? ›- Operational savings from hassle-free firmware upgrades, solution automation with Cisco Intersight and operational simplification with smart zoning.
- Increased uptime with Cisco support and a single pane of glass for unified visibility, combined with deep traffic analysis and proactive troubleshooting.
“Intersight is subsuming and replacing UCS Central,” Todd Brannon, director of product marketing at Cisco, told ServerWatch. “All the functionally we had in UCS Central, that's what Intersight has been built to replace and expand.”
What are the default credentials for fabric OS? ›Brocade fibre channel switches containing the Fabric OS (FOS) will be delivery with the preconfigured default accounts admin, root and user. It is important not to use default passwords in a productive environment, so therefor please change the passwords.
What is the default ID and password for cisco? ›The default username is cisco. The default password is cisco.
What is the admin password for cisco room kit? ›The default user name is admin with no passphrase set.
What is required to cluster a pair of fabric interconnects? ›
To use the cluster configuration, the two fabric interconnects must be directly connected together using Ethernet cables between the L1 (L1-to-L1) and L2 (L2-to-L2) high availability ports, with no other fabric interconnects in between.
Which cable type must be used to interconnect one switch? ›Normal Ethernet Cables
This type of cable is a “regular” or straight-through cable. You use this type of cable to connect a PC to a hub/switch or a router to a switch.
At the fabric interconnect, the server-facing Ethernet port receives the Ethernet and Fibre Channel traffic.
What is the default IP for cisco manage switch? ›To access the switch by using the web-based interface, you must know the IP address the switch is using. The switch uses the factory default IP address of 192.168. 1.254 by default. When the switch is using the factory default IP address, the System LED flashes continuously.
What is the default admin password for Cisco UCS Director? ›Default Root and Shelladmin Passwords
Root user for the CentOS operating system of the Cisco UCS Director VM. The default password is cisco123.
Most routers and switches by Cisco have default passwords of admin or cisco, and default IP addresses of 192.168. 1.1 or 192.168. 1.254.
What is Cisco switch fabric module? ›Switch Fabric Overview
The switch fabric is the core of the Cisco CRS 4-slot line card chassis. The switch fabric is implemented through switch fabric cards installed in the chassis. The switch fabric uses a cell-switched, buffered three-stage Benes switch fabric architecture.
If you are using blade servers, you must have FEXes in the back of it to provide connectivity to the Cisco UCS system. The FEXes are connected to the Fabric Interconnects. There are two FEX slots in the Blade Chassis, one for A side connectivity and one for B side connectivity.
What is meant by switch fabric? ›Switched fabric or switching fabric is a network topology in which network nodes interconnect via one or more network switches (particularly crossbar switches).
What is the difference between install and bundle mode Cisco? ›The Install mode and the Bundle mode of operation have the following restrictions: Booting from a USB driver or TFTP in Install mode is not supported. Booting the switch in Bundle mode consumes more memory than the Install mode because the packages are extracted from the bundle and copied to the RAM.
What is Cisco fabric path? ›
Cisco FabricPath is an innovation in Cisco NX-OS Software that uses routing principles to allow Layer 2 scaling in a way that was not possible before. This technology provides the flexibility and the performance required to make data centers a service for the applications that use them.
What is Cisco fabric services Protocol? ›Cisco Fabric Services (CFS) provides a common infrastructure for automatic configuration synchronization in the network. It provides the transport function and a set of common services to the features.
What does Cisco FEX stand for? ›Cisco Nexus Switches are sometimes used with Nexus 2000 Series Fabric Extenders (FEX) units. These separate units provide additional Ports for some Nexus 5000, 7000 or 9000 series switches, and have an up-link connection to the main Switch.
Which mode must be enabled on a Cisco UCS fabric interconnect to connect directly to a storage array? ›Switch mode allows the fabric interconnect to connect directly to a storage device.
Which is the default mode of fabric interconnect? ›The default switching mode is the EHM, which eliminates the use of the Spanning Tree Protocol (STP) on Fabric Interconnect.
How many ports does the Cisco UCS 6324 fabric interconnect module have in Cisco UCS Mini? ›40 Gbps QSFP+ port plus 4 uplink SFP+ ports * 10Gbps plus 16 server internal ports * 10 Gbps plus 1 crosslink port * 10Gbps = 250 Gbps.
How do I enable CDP on Cisco fabric interconnect? ›To enable CDP the first thing you must do is to create a new Network Control policy. To do this go to the LAN tab in UCSM, expand Policies, right-click Network Control Policies to create a new policy. Name it something like “Enable-CDP” and select the option to enable CDP.